CONTACT US | MORE DETAIL |
WENGLOR Safety Technology
Wenglor’s technologically advanced safety products solve demanding safety relevant tasks in the field of automation. wenglor safety products protect people and safeguard machinery – and they’re certified in accordance with the latest international standards. wenglor is continuously expanding appropriate customer service offerings in this area. Specially trained service technicians support wenglor’s customers during initial start-up, and conduct periodic testing on a regular basis.
CONTACT US |
WENGLOR Safety Through Beam Sensors
The Individual Safety Light Barrier Control Unit or a suitable Safety Control Unit observes the safety field of up to four Individual Safety Light Barriers. The Sensors secure areas up to 60 m. The visible red light and large opening angle make the setup easy and saves valuable startup time. The safety function can be tested at any time over the test input.
SL2-00NE000H2
|
0...20
m
|
14 × 33
× 67 mm
|
|
SL2-00NE000H3
|
0...20
m
|
14 × 33
× 67 mm
|
|
SL2-00NS000H2
|
0...20
m
|
14 × 33
× 67 mm
|
Red
Light
|
SL2-00NS000H3
|
0...20
m
|
14 × 33
× 67 mm
|
Red
Light
|
SL2-00TE000H1
|
5...60
m
|
34 × 73
× 75 mm
|
|
SL2-00TS000H2
|
5...60
m
|
34 × 73
× 75 mm
|
Red
Light
|
WENGLOR Individual Safety Light Barrier Control Unit
The Individual Safety Light Barrier Control Unit observes the safety field of up to 4 Individual Safety Light Barriers. If one or more light beams are interrupted, the safety output switches off. The rugged Individual Safety Light Barriers together with the Individual Safety Light Barrier Control Units are the perfect team for protecting humans and machines.
SS2-00VA000R2
|
Individual
Safety Light Barrier Control Unit
|
SS2-00VA000R3
|
Individual
Safety Light Barrier Control Unit
|
CONTACT US |
WENGLOR Safety Light Curtain Type 2 for Connection Unit A
The Safety Integrity Light Curtain Type 2 together with the Connection Unit A offers hand protection (Resolution 30 mm) through Performance Level d (PL d) and Safety Integrity Level 2 (SIL 2). Thanks to the slender housing, the visible red light and the simple configuration via DIP switch, a quick and secure startup is possible. Up to 2 transmitter and receiver units can be connected to the central Connection Unit and then be cascaded.
SG2-30BE021C2
|
0,25...8
m
|
214 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE039C2
|
0,25...8
m
|
398 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE058C2
|
0,25...8
m
|
582 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE076C2
|
0,25...8
m
|
766 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE095C2
|
0,25...8
m
|
950 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE113C2
|
0,25...8
m
|
1134 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE131C2
|
0,25...8
m
|
1318 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE150C2
|
0,25...8
m
|
1502 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE168C2
|
0,25...8
m
|
1686 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BE187C2
|
0,25...8
m
|
1870 mm
|
17,6 ×
31,7 mm
|
|
SG2-30BS021C2
|
0,25...8
m
|
214 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS039C2
|
0,25...8
m
|
398 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS058C2
|
0,25...8
m
|
582 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS076C2
|
0,25...8
m
|
766 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS095C2
|
0,25...8
m
|
950 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS113C2
|
0,25...8
m
|
1134 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS131C2
|
0,25...8
m
|
1318 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS150C2
|
0,25...8
m
|
1502 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS168C2
|
0,25...8
m
|
1686 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
SG2-30BS187C2
|
0,25...8
m
|
1870 mm
|
17,6 ×
31,7 mm
|
Red
Light
|
CONTACT US |
WENGLOR Connection Unit A for SG2-30B
The Safety Integrity Light Curtain Type 2 together with the Connection Unit A offers hand protection (Resolution 30 mm) through Performance Level d (PL d) and Safety Integrity Level 2 (SIL 2). Thanks to the slender housing, the visible red light and the simple configuration via DIP switch, a quick and secure startup is possible. Up to 2 transmitter and receiver units can be connected to the central Connection Unit and then be cascaded.
Applications
- Safeguarding for machines
- Safeguarding for saws
- Access monitoring
- Safeguarding for palletizing equipment
- Safeguarding for packaging machines
Certified Safety
The Safety Light Barriers comply with PL d according to EN ISO 13849-1 as well as SIL 2 according to EN 62061 / EN 61508. These high safety demands have been certified and approved by the TÜV South. They are ESPE type 2 according to EN 61496.
Operating and Function modes
The Safety Light Barriers generally integrate various operating modes (Fix Blanking) and function modes (Safety Operating Mode, Restart Inhibit, Contactor Monitoring, Muting).
Outputs
The Connection Unit A has 2 safety orientated semiconductor outputs. The version R2 has 2 safety orientated and potential free relay outpus.
Strong Team
The Safety Light Barrier with its slender and compact housing is suitable for almost every space situation. The Connection Unit A completes the system and enables a very easy configuration.
SG2-00AA000H2
|
Connection
Unit A
|
for
SG2-30B
|
SG2-00AA000R2
|
Connection
Unit A
|
for
SG2-30B
|
CONTACT US |
Safety Light Curtain Type 2 Finger Protection
Safety Light Curtains Type 2 provide finger protection (Resolution 14 mm) and hand protection (Resolution 30 mm) according to Performance Level d (PL d). Thanks to the visible red light and the simple configuration via DIP switch and the free wenglor software a quick, easy and secure startup is possible. The evaluation electronic is integrated in the transmitter, so the Safety Light Curtain can be mounted in a space-saving way. Combined with the relay unit, safety oriented load circles are switchable.
SG2-14IE015C1
|
0,25...7
m
|
164 mm
|
40,2 ×
47,1 mm
|
|
SG2-14IE030C1
|
0,25...7
m
|
314 mm
|
40,2 ×
47,1 mm
|
|
SG2-14IE045C1
|
0,25...7
m
|
464 mm
|
40,2 ×
47,1 mm
|
|
SG2-14IE060C1
|
0,25...7
m
|
614 mm
|
40,2 ×
47,1 mm
|
|
SG2-14IE075C1
|
0,25...7
m
|
764 mm
|
40,2 ×
47,1 mm
|
|
SG2-14IE090C1
|
0,25...7
m
|
914 mm
|
40,2 ×
47,1 mm
|
|
SG2-14IE105C1
|
0,25...7
m
|
1064 mm
|
40,2 ×
47,1 mm
|
|
SG2-14IS015C1
|
0,25...7
m
|
164 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-14IS030C1
|
0,25...7
m
|
314 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-14IS045C1
|
0,25...7
m
|
464 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-14IS060C1
|
0,25...7
m
|
614 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-14IS075C1
|
0,25...7
m
|
764 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-14IS090C1
|
0,25...7
m
|
914 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-14IS105C1
|
0,25...7
m
|
1064 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
Safety Light Curtains Type 2 provide finger protection (Resolution 14 mm) and hand protection (Resolution 30 mm) according to Performance Level d (PL d). Thanks to the visible red light and the simple configuration via DIP switch and the free wenglor software a quick, easy and secure startup is possible. The evaluation electronic is integrated in the transmitter, so the Safety Light Curtain can be mounted in a space-saving way. Combined with the relay unit, safety oriented load circles are switchable.
SG2-30IE015C1
|
0,5...20
m
|
180 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE030C1
|
0,5...20
m
|
330 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE045C1
|
0,5...20
m
|
480 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE060C1
|
0,5...20
m
|
630 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE075C1
|
0,5...20
m
|
780 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE090C1
|
0,5...20
m
|
930 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE105C1
|
0,5...20
m
|
1080 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE120C1
|
0,5...20
m
|
1230 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE135C1
|
0,5...20
m
|
1380 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE150C1
|
0,5...20
m
|
1530 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE165C1
|
0,5...20
m
|
1680 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IE180C1
|
0,5...20
m
|
1830 mm
|
40,2 ×
47,1 mm
|
|
SG2-30IS015C1
|
0,5...20
m
|
180 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS030C1
|
0,5...20
m
|
330 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS045C1
|
0,5...20
m
|
480 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS060C1
|
0,5...20
m
|
630 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS075C1
|
0,5...20
m
|
780 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS090C1
|
0,5...20
m
|
930 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS105C1
|
0,5...20
m
|
1080 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS120C1
|
0,5...20
m
|
1230 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS135C1
|
0,5...20
m
|
1380 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS150C1
|
0,5...20
m
|
1530 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS165C1
|
0,5...20
m
|
1680 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG2-30IS180C1
|
0,5...20
m
|
1830 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
CONTACT US |
Safety Light Curtain Type 4 Finger Protection
Safety Light Curtains Type 4 provide finger protection (Resolution 14 mm) and hand protection (Resolution 30 mm) according to Performance Level e (PL e). Thanks to the visible red light and the simple configuration via DIP switch and the free wenglor software a quick, easy and secure startup is possible. The evaluation electronic is integrated in the transmitter, so the Safety Light Curtain can be mounted in a space-saving way. Combined with the relay unit, safety oriented load circles are switchable.
SG4-14IE015C1
|
0,25...7
m
|
164 mm
|
40,2 ×
47,1 mm
|
|
SG4-14IE030C1
|
0,25...7
m
|
314 mm
|
40,2 ×
47,1 mm
|
|
SG4-14IE045C1
|
0,25...7
m
|
464 mm
|
40,2 ×
47,1 mm
|
|
SG4-14IE060C1
|
0,25...7
m
|
614 mm
|
40,2 ×
47,1 mm
|
|
SG4-14IE075C1
|
0,25...7
m
|
764 mm
|
40,2 ×
47,1 mm
|
|
SG4-14IE090C1
|
0,25...7
m
|
914 mm
|
40,2 ×
47,1 mm
|
|
SG4-14IE105C1
|
0,25...7
m
|
1064 mm
|
40,2 ×
47,1 mm
|
|
SG4-14IS015C1
|
0,25...7
m
|
164 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-14IS030C1
|
0,25...7
m
|
314 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-14IS045C1
|
0,25...7
m
|
464 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-14IS060C1
|
0,25...7
m
|
614 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-14IS075C1
|
0,25...7
m
|
764 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-14IS090C1
|
0,25...7
m
|
914 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-14IS105C1
|
0,25...7
m
|
1064 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
CONTACT US |
WENGLOR Safety Light Curtain Type 4 Hand Protection
Safety Light Curtains Type 4 provide finger protection (Resolution 14 mm) and hand protection (Resolution 30 mm) according to Performance Level e (PL e). Thanks to the visible red light and the simple configuration via DIP switch and the free wenglor software a quick, easy and secure startup is possible. The evaluation electronic is integrated in the transmitter, so the Safety Light Curtain can be mounted in a space-saving way. Combined with the relay unit, safety oriented load circles are switchable.
SG4-30IE015C1
|
0,5...20
m
|
180 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE030C1
|
0,5...20
m
|
330 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE045C1
|
0,5...20
m
|
480 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE060C1
|
0,5...20
m
|
630 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE075C1
|
0,5...20
m
|
780 mm
|
40,2 × 47,1
mm
|
|
SG4-30IE090C1
|
0,5...20
m
|
930 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE105C1
|
0,5...20
m
|
1080 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE120C1
|
0,5...20
m
|
1230 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE135C1
|
0,5...20
m
|
1380 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE150C1
|
0,5...20
m
|
1530 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE165C1
|
0,5...20
m
|
1680 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IE180C1
|
0,5...20
m
|
1830 mm
|
40,2 ×
47,1 mm
|
|
SG4-30IS015C1
|
0,5...20
m
|
180 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS030C1
|
0,5...20
m
|
330 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS045C1
|
0,5...20
m
|
480 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS060C1
|
0,5...20
m
|
630 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS075C1
|
0,5...20
m
|
780 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS090C1
|
0,5...20
m
|
930 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS105C1
|
0,5...20
m
|
1080 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS120C1
|
0,5...20
m
|
1230 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS135C1
|
0,5...20
m
|
1380 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS150C1
|
0,5...20
m
|
1530 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS165C1
|
0,5...20
m
|
1680 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
SG4-30IS180C1
|
0,5...20
m
|
1830 mm
|
40,2 ×
47,1 mm
|
Red
Light
|
CONTACT US |
WENGLOR Safety Light Array Type 2 Body Protection
The Safety Light Arrays provide body protection and keep persons from unintended entering into dangerous areas. Thanks to the visible red light and the simple configuration via the DIP switches and the free wenglor software, a quick, easy and secure startup is possible. The evaluation electronics are integrated in the transmitter, so the Safety Light Array can be mounted in a space-saving way. Combined with the relay unit, safety oriented load circles are switchable.
SB2-30IE090C1
|
0,5...20
m
|
40,2 ×
47,1 mm
|
4
|
|
SB2-30IS090C1
|
0,5...20
m
|
40,2 ×
47,1 mm
|
Red
Light
|
4
|
SB2-40IE080C1
|
0,5...20
m
|
40,2 × 47,1
mm
|
3
|
|
SB2-40IS080C1
|
0,5...20
m
|
40,2 ×
47,1 mm
|
Red
Light
|
3
|
SB2-50IE050C1
|
0,5...20
m
|
40,2 ×
47,1 mm
|
2
|
|
SB2-50IS050C1
|
0,5...20
m
|
40,2 × 47,1
mm
|
Red
Light
|
2
|
WENGLOR Safety Light Array Type 4 Body Protection
The Safety Light Arrays provide Body Protection and keep persons from unintended entering into dangerous areas. Thanks to the visible red light and the simple configuration via the DIP switches and the free wenglor software, a quick, easy and secure startup is possible. The evaluation electronics are integrated in the transmitter, so the Safety Light Array can be mounted in a space-saving way. Combined with the relay unit, safety oriented load circles are switchable.
0,5...20
m
|
40,2 ×
47,1 mm
|
4
|
||
SB4-30IS090C1
|
0,5...20
m
|
40,2 ×
47,1 mm
|
Red
Light
|
4
|
SB4-40IE080C1
|
0,5...20
m
|
40,2 ×
47,1 mm
|
3
|
|
0,5...20
m
|
40,2 ×
47,1 mm
|
Red
Light
|
3
|
|
SB4-50IE050C1
|
0,5...20
m
|
40,2 ×
47,1 mm
|
2
|
|
0,5...20
m
|
40,2 ×
47,1 mm
|
Red
Light
|
2
|
CONTACT US |
WENGLOR Relay Unit Type 2/Type 4
The Relay Unit enables the switching of safety oriented load circles, there are two safety oriented Relay Outputs are available. They are constructed for a connection to Safety Light Curtains Type 2 and 4 and can be integrated easily into the switching cycle by means of Terminal Blocks.
Relay
Unit Type 2/Type 4
|
CONTACT US |
WENGLOR Protection Column with Screening Grid
The Protection Columns protect the Safety Light Curtains against mechanical influences. The versions with Screening Grid enable a free-standing mounting of the Safety Light Curtains. The cable could come out at top or bottom of the column. By means of the Protection Column with Deflection Mirror an efficient all-round protection is possible. The Protection Column program is completed by useful accessories. Mounting Brackets are already included in delivery.
Protection
Column
|
with
Screening Grid
|
930 mm
|
|
SZ000EG170NN01
|
Protection
Column
|
with
Screening Grid
|
1380 mm
|
Protection
Column
|
with
Screening Grid
|
1830 mm
|
The Protection Columns protect the Safety Light Curtains against mechanical influences. The versions with Screening Grid enable a free-standing mounting of the Safety Light Curtains. The cable could come out at top or bottom of the column. By means of the Protection Column with Deflection Mirror an efficient all-round protection is possible. The Protection Column program is completed by useful accessories. Mounting Brackets are already included in delivery.
Protection
Column
|
with
Deflection Mirror
|
930 mm
|
|
SZ000EU170NN01
|
Protection
Column
|
with
Deflection Mirror
|
1380 mm
|
Protection
Column
|
with
Deflection Mirror
|
1830 mm
|
MORE DETAIL
No comments:
Post a Comment